Description
Trung tâm báo cháy Unipos IFS7002 1 Loop được thiết kế để điều khiển các thiết bị báo cháy địa chỉ tự động và nút nhấn khẩn. Nó điều khiển các thiết bị địa chỉ và tích hợp các thiết bị đầu vào-đầu ra vào các Loop báo cháy.
Technical data Unipos IFS 7002
Physical configuration:– 1 fire alarm loop |
|
Fire alarm zones:– Maximum number of zones |
64 |
Fire alarm loop:– Maximum number of fire detectors in a loop |
125 |
Monitored outputs: – Type – Electrical characteristics |
2 pcs potential (24±5)V/0,5A |
Relay output for fire conditions: – Type – Electrical characteristics |
1 pc potential free, switching 3A/125VAC; 3A/30VDC |
Relay (programmable) output for fire conditions: – Type – Electrical characteristics |
1 pc potential free, switching 3A/125VAC; 3A/30VDC |
Relay output for fault conditions: – Type – Electrical characteristics |
1 pc potential free, switching 3A/125VAC; 3A/30VDC |
Performance:
– Control over fire alarm loops and monitored outputs for fault conditions (short circuit and interruption) and automatic reset.
– Detection of removed devices in the loops and automatic reset.
– Ability to set the zones in Coincidence Mode.
– Two phases of Fire condition, programmable time for Fire condition stage I, separately for each zone.
– Option to prolong the time period for Fire condition stage I with programmable inspection period, specified for each zone.
– Built-in sounder for fire condition – one tonal, discontinuous, can be switched off.
– Built-in sounder for fault condition – one tonal, discontinuous, can be switched off.
– Built-in real time clock.
– Set of test modes and options for adjustment:
¨ Setting the clock;
¨ Check ups on light and sound indications;
¨ Test of fire alarm zones;
¨ Adjustment of outputs and integrated external devices;
¨ Programming of parameters and modes of operation;
¨ Remote programming of the parameters from distant operator control point.
– Energy independent archive of registered events with the events type, date and hour – up to 1023 events.
– Interfaces for communication with external devices – CAN 2.0B and RS-232 (directly or via modem).
Indications of registered events:– Light indication – Sound signaling |
LEDLCD display, 320×240 points, backing |
Power supply:– Mains – Back up batteriesBattery type – Consumption on back up batteries supplyAt 24V – Power supply to external devicesVoltage |
220/230 V lead, gel electrolyte < 160 mA (24±5)V |
Dimension |
286x148x125 mm |
Weight (batteries not included) |
2,2 kg |